See our Fronius IG Plus inverter prices.
Fronius IG Plus Inverters
For
grid-tied applications, the
next generation Fronius IG Plus inverter builds on a successful model with
multiple enhancements, including maximum power harvest, a built-in six
circuit string combiner, integrated, lockable DC Disconnect, significantly
improved efficiency, and unbeatable reliability. New, larger power classes
expand the proven Fronius IG family (from 3.0 to 12 kW) and provide
consistently high earnings.
|
Fronius IG Plus Model
|
3.0-1
|
3.8-1
|
5.0-1
|
6.0-1
|
7.5-1
|
|
Input Data
|
|
Recommended PV-Power (Wp)
|
2500-3450
|
3200-4400
|
4250-5750
|
5100-6900
|
6350-8600
|
|
MPPT-Voltage range
|
230 - 500 V
|
|
Max. Input voltage
range
(at 1000 W/m² 14°F (-10°C) in open circuit operation)
|
600 V
|
|
Nominal Input Current
|
8.3A
|
10.5A
|
13.8A
|
16.6A
|
20.7A
|
|
Max. usable Input Current
|
14.0A
|
17.8A
|
23.4A
|
28.1A
|
35.1A
|
|
Admissible conductor size
(DC)
|
No. 14-6 AWG
|
|
Output data
|
|
Nominal output power (PAC
nom)
|
3000W
|
3800W
|
5000W
|
6000W
|
7500W
|
|
Max. continuous
output power
104°F (40°C) 208 V / 240 V / 277 V
|
3000W
|
3800W
|
5000W |
6000W |
7500W |
|
Nominal frequency
|
60 Hz
|
|
Operating frequency range
|
59.3 - 60.5 Hz
|
|
Total harmonic distortion
|
< 3 %
|
|
Power factor
|
1
|
|
General data
|
|
Max. Efficiency
|
96.2 %
|
|
CEC Efficiency
208 V
240 V
277 V
|
95.0 %
95.5 %
95.5 %
|
95.0 %
95.5 %
95.5 %
|
95.5 %
95.5 %
96.0 %
|
95.5 %
96.0 %
96.0 %
|
95.0 %
95.5 %
96.0 %
|
|
Consumption in standby
(night)
|
<1 W
|
|
Consumption during
operation
|
8 W
|
15 W
|
|
Cooling
|
Controlled forced ventilation, variable
fan speed
|
|
Enclosure Type
|
NEMA 3R
|
|
Unit Dimensions
(W x H x D)
|
17.1 x 24.8 x 9.6. in.
|
17.1 x 36.4 x 9.6. in.
|
|
Power Stage Weight
|
31 lbs. (14 kg)
|
57 lbs. (26 kg)
|
|
Wiring Compartment Weight
|
24 lbs. (11 kg)
|
26 lbs. (12 kg)
|
|
Admissing ambient operating
temperature
|
-4 ... 122°F (-20 ... + 50°C)
|
|
Compliance
|
UL 1741-2005, IEEE1547-2003, IEEE
1547.1, ANSI/IEEE C62.41,
FCC Part 15 A&B, NEC Article 690, C22. 2 No. 107.1-01
(Sept. 2001)
|
|
Safety equipment
|
|
Ground fault protection
|
Internal GFDI (Ground Fault
Detector/Interrupter); in accordance with UL 1741-2005 and NEC Art.
690
|
|
DC reverse polarity
protection
|
Internal diode
|
|
Islanding protection
|
Internal; in accordance with UL
1741-2005,
IEEE 1547-2003 and NEC
|
|
Over temperature
|
Output power derating / active cooling
|